Energy scan for multiple consecutive energy regions, with equal or different step (variable point density). EXAMPLE
| ||||||
Macros:
Usage: XEscan start end1 intervals1 [end2 intervals2 ...] time ["fixQ"] Extended Escan. You can define as many ends and intervals as you want. If only one - does a normal Escan. The enrgy is in KeV, the time in s. The literal \"fixQ\" means keep HKL constant. | ||||||
Internal Macros: | ||||||
Usage: XEscan_usage Print out XEscan macro usage and exit XEscanf Usage: XEscanf (xepar,nbinp) Do extended energy scan with xepar parameters for nbinp inputs. _XEchk Usage: _XEchk (no, v) Check the XEscan no - number of input parameters and set the fix HKL flag if v is \"fixQ\". Return 0 if OK, -1 if error. _XEcalcsteps Usage: _XEcalcsteps (xepars) Fills in the global float array (XE_STEPS) with each scan steps. _XEscan Usage: _XEscan start finish intervals time [fixQ] Modified Escan. | ||||||
|