Description:
| ||||||
Documentation:
Implement macro motors and macro counters to control the regulation loop and to read any MODBUS address from the controller. For the macro counters, the channel is used to defined the MODBUS address to read. But as a scaler controller can only have 999 channels, to read a higher address, there is an optional counter parameter named "address". When MODBUS address to read is defined like than, there is a second optional parameter named "floatvalue" to get a float value from the controller instead of a rounded temperature value. $Revision: 1.12 $ Package bliss version 1.2 is corrupted. need modbus-rtu.mac if (!(whatis("__e2700debug") & 2)) rdef __e2700debug \'#$*\' INTERNALS | ||||||
Macros:
Usage: e2700_debug toggle debug mode for the present macros. euro2700status Usage: euro2700status [unit] Gives information about the status of the controller. Not to confuse with europrogstatus, which gives information about a program execution in the controller. This one reads the status bytes on a controller and puts them out in human readable form. Saves you to rtfm. The bits of the fast status read (tag 75) are as follows: 0 Alarm 1 State ( 0 = Safe, 1 = Alarm )After reflexion, Ill give you all that is there :-), 74 to 77 euro2700showpid Usage: euro2700showpid unit Show the PID values for unit euro2700configuration Usage: euro2700configuration Please run without arguments to find out about the possible actions. Put controller into configuration mode and set one of several special cells. The following values influence the macros considerably. They can be set from the computer to make the user experience less painful. Note: no spaces are allowed around the `=` signs! Note: the decimal display will only be valid, if the Resolution is set to 0 (full)!!!
| ||||||
Internal Macros: | ||||||
Usage: __e2700_put (unit, fwaddr, value) __e2700_blockput Usage: __e2700_blockput (unit, fwaddr, num, data) __e2700_get Usage: __e2700_get (unit, fwaddr, num, data) __e2700_put_serial Usage: __e2700_put_serial (node, fwaddr, value) Called by spec __e2700_blockput_serial Usage: __e2700_blockput_serial (node, fwaddr, value) Called by spec __e2700_get_serial Usage: __e2700_get_serial (fwaddr, fwaddr, num, data) Called by spec __e2700_put_tango Usage: __e2700_put_tango (fwaddr, value) (server, fwaddr, value) Called by spec __e2700_blockput_tango Usage: __e2700_blockput_tango (server, fwaddr, nwords, data) Called by spec __e2700_get_tango Usage: __e2700_get_tango (server, fwaddr, num, data) Called by spec.<BR>data is ushort array __e2700_rfloat Usage: __e2700_rfloat(unit, val) __e2700_wfloat Usage: __e2700_wfloat(unit, val) E2700_config Usage: E2700_config (mne, type, unit, mod, chan) Called by spec E2700_cmd Usage: E2700_cmd(mne, cmd, p1, p2, p3) Called by spec E2700_par Usage: E2700_par(num, key, action, p1, p2) Called by spec with different keys to handle motor_par(mot,"key",new_value) and counter_par(cnt,"key") actions. __euro__float Usage: __euro__float (<data>) Converts 4 byte size values into IEEE floating point value and returns it. The 2408 can be put into a floating point mode (read cell 12275) which then displays values with variable number of floating point numbers. To avoid getting in trouble with that, the protocol allows to read 4 bytes from adresses over 0x8000. Thus, the cell 2 reads from 2 x 2 + 8000h = 8004h = 32772 decimal. __e2700_simple Usage: __e2700_simple | ||||||
|