Beamline Instrument Software Support |
|
SPEC Macro documentation:
[ Macro Index |
BCU Home ]
|
par263.mac $Revision: 1.8 $ | ||||||
[ source code | installed at | configured at ] | ||||||
See other macros in category: All | ||||||
Description:
| ||||||
Documentation:
SETUP | ||||||
Macros:
Usage: par263setup <gpib_addr> <potential_mne> <current_cnt> Global setup. The potential unit will be mV and the current unit will be A (use the scale factor in config to change the sign and the scale) pct Usage: pct %MDESC count with autorange on par263unsetup Usage: par263unsetup par263on Usage: par263on Activates pseudo motor/counters par263off Usage: par263off De-activates pseudo motor/counters par263acq Usage: par263acq [<time_in_sec>] Test curve acquisition par263report Usage: par263report Report information on last curve acquired par263mode Usage: par263mode [<mode>] Without <mode>, report the current controller mode With <mode> specified, change the mode Possible modes are: (1) Galvanostat (2) Potentiostat par263readI Usage: par263readI Read 10 I samples and return average par263readE Usage: par263readE Read 10 E samples and return average par263setE Usage: par263setE [<set_potential>] Read/Write set potential (unit=mV) par263reset Usage: par263reset Reset default controller parameters par263error Usage: par263error Report error status on last command executed par263cell Usage: par263cell [<0|1>] Without argument: report cell status With argument: 0= set cell OFF 1= set cell ON par263dummy Usage: par263dummy [<0|1>] Without argument, report dummy cell status With argument: 0= set dummy cell OFF 1= set dummy cell ON par263talk Usage: par263talk Interactive session par263vertex Usage: par263vertex init_pot down_pot up_pot slope ppsec Generate a single vertex from init_pot to down_pot, then up to up_pot and finally down to init_pot. All the potentials are in mV. The slope will be given in mV/sec. The parameter ppsec is the number of points per second par263gsetup Usage: par263gsetup <gpib_addr> <potential_cnt> <current_cnt> Global setup. The potential unit will be mV and the current unit will be mA (use the scale factor in config to change the sign and the scale) par263gon Usage: par263gon Activates pseudo motor/counters | ||||||
Internal Macros: | ||||||
Usage: _par263_print (msg, err) par263_body Usage: par263_body(mode) body macro for blmenu _par263_startcurve Usage: _par263_startcurve (acquisition_time) Start curve acquisition _par263_waitcurve Usage: _par263_waitcurve () Return 1 if curve still in acquisition _par263_stopcurve Usage: _par263_stopcurve () Stop a curve acquisition _par263_readcurve Usage: _par263_readcurve () Read curve minimum, maximum, integral _par263_checkall Usage: _par263_checkall _par263_getpangles Usage: _par263_getpangles _par263_getEcounts Usage: _par263_getEcounts _par263_getPcounts Usage: _par263_getPcounts _par263_getinstantaneousIcounts Usage: _par263_getinstantaneousIcounts _par263_getIcounts Usage: _par263_getIcounts _par263_prepcount Usage: _par263_prepcount _par263_cleanup Usage: _par263_cleanup _par263_checkid Usage: _par263_checkid () _par263_write Usage: _par263_write (cmd) _par263_io Usage: _par263_io (cmd) _par263_read Usage: _par263_read () _par263_talkusage Usage: _par263_talkusage __upper Usage: __upper(str) _par263vertex_plot Usage: _par263vertex_plot(n) Get from the VERSASTAT the contains of its CURVE buffers and plot them This macro expect I in the CURVE_0 and E in CURVE_1 par263setI Usage: par263setI | ||||||
|