TANGO
Device Server



Tango TuneServer
Device Attributes Description

TuneServer2 Class

Revision: TuneServer2-Release_1_1 - Author: verdier

Scalar Attributes
Attribute name
Data Type
R/W Type
Expert
FreqMin: The signal analyze will start from this frequency.
DEV_DOUBLE
READ_WRITE
No
FreqMax: The signal analyze will stop at this frequency.
DEV_DOUBLE
READ_WRITE
No
SweepTime: This is the wanted spweep time duration. The device will correct value to it's capabilities.
DEV_DOUBLE
READ_WRITE
No
NbAverage: This is the averaging factor on 4395a.
DEV_SHORT
READ_WRITE
No
BandWidth: This is the resolution bandwidth (freq filter range).
DEV_DOUBLE
READ_WRITE
No
ReferenceLevel: This is A4395a display reference level.
DEV_DOUBLE
READ_WRITE
No
DScale: This is the scale of A4395a's display.
DEV_DOUBLE
READ_WRITE
No
AcquisitionMode: This string attribute represents measure made on the 4395a. Authorised values are A, B, R, AR, BR.
DEV_STRING
READ_WRITE
Yes
InputAttenA: This is the value of attenuation applied on A4395a input port A. Autorized values: 0, 10, 20, 30, 40, 50.
DEV_SHORT
READ_WRITE
Yes
InputAttenB: This is the attenuation applied on A4395a input port B. Autorized values: 0, 10, 20, 30, 40, 50.
DEV_SHORT
READ_WRITE
Yes
InputAttenR: This is the attenuation applied on A4395a input port R. Autorized values: 0, 10, 20, 30, 40, 50.
DEV_SHORT
READ_WRITE
Yes
TriggerSource: This is the trigger source of the Agilent 4395a.
DEV_STRING
READ_WRITE
Yes
Averaging: This is the Averaging of the 4395a flag. True mean that averaging is performed on the spectrum.
DEV_BOOLEAN
READ_WRITE
No
TrackSpan: This is the bandwidth where peak should be tracked.
DEV_DOUBLE
READ_WRITE
Yes
PeakHCenter: This is the Horizontal peak index in the spectrum attribute.
DEV_SHORT
READ_WRITE
Yes
PeakVCenter: This is the vertical peak index in the Spectrum attribute.
DEV_SHORT
READ_WRITE
Yes
TrackSpanWidth: This is the conversion of trackspan to pixel width.
DEV_SHORT
READ
Yes
Shaker: Indicates if shaker is on or off.
DEV_BOOLEAN
READ_WRITE
No
PeakHLevel: Amplitude of the Horizontal Peak.
DEV_DOUBLE
READ
Yes
PeakVLevel: This is the level of vertical peak.
DEV_DOUBLE
READ
Yes
SpareHShaker
DEV_BOOLEAN
READ_WRITE
No
SpareVShaker:
DEV_BOOLEAN
READ_WRITE
No
DataAcquisition: This attribute shows if agilent 4395a is getting data or not. Technicaly, it switch 4395a trigger source to HOLD or CONT, which start / stop data aquisition.
DEV_BOOLEAN
READ_WRITE
No
TuneQH: This is the Horizontal tune value.
DEV_DOUBLE
READ
No
TuneQV: This is the Vertical tune value .
DEV_DOUBLE
READ
No
Timer1: This attribute wraps a taco-controled VDPU board.
DEV_DOUBLE
READ_WRITE
Yes
Timer2: This attribute wraps a taco-controled VDPU board.
DEV_DOUBLE
READ_WRITE
Yes
Timer3: This attribute wraps a taco-controled VDPU board.
DEV_DOUBLE
READ_WRITE
Yes
ShakerPlane: This is the plane that is shaked by shaker.
DEV_STRING
READ_WRITE
No
MeasurePlane: This is the plane that is used for measures.
DEV_STRING
READ_WRITE
No
ShakerStrengthH: Shaker horizontal strength.
DEV_DOUBLE
READ_WRITE
Yes
ShakerStrengthV: Shaker Vertical Strength.
DEV_DOUBLE
READ_WRITE
Yes
ShakerLevel: This is the 4395a output level.
DEV_DOUBLE
READ_WRITE
No
ConfigFileName
DEV_STRING
READ
No
RefCurveFreqMin
DEV_DOUBLE
READ
No
RefCurveFreqMax
DEV_DOUBLE
READ
No





Spectrum Attributes
Attribute name
Data Type
X Data Length
Expert
Spectrum: This is the spectrum resulting from A4395 operations.
DEV_DOUBLE
800
No
ReferenceCurve
DEV_DOUBLE
800
No







TANGO is an open source project hosted by :
Sourceforge logo small
Core and Tools : CVS repository on tango-cs project
Device Servers : CVS repository on tango-ds project