Table 3
ID |
APPLICATION |
FIELD (t) |
PERIOD |
GAP (mm) |
TYPE |
1 |
Anomalous Scattering |
0.85 |
70 |
16 |
Wiggler |
1 |
|
0.56 |
42 |
16 |
Undulator |
2 |
High Brilliance |
0.48 |
46 |
20 |
Undulator |
2 |
|
0.16 |
26 |
20 |
Undulator |
3 |
Surface Diffraction |
0.48 |
46 |
20 |
Undulator |
6 |
Machine Diagnostics |
0.50 |
48 |
20 |
Undulator |
9 |
White Beam |
0.85 |
70 |
16 |
Wiggler |
9 |
|
0.62 |
46 |
16 |
Undulator |
10 |
Open/Troika |
0.48 |
46 |
20 |
Undulator |
10 |
|
0.71 |
26 |
7 |
Minigap undulator |
11 |
Materials Science |
1.20 |
125 |
20 |
Wiggler |
12 |
Circular Polarisation |
0.51 |
85 |
16 |
Helical undulator |
12 |
|
0.36 |
52 |
16 |
Helical undulator |
13 |
Microfocus |
0.65 |
46 |
16 |
Undulator |
14 |
Protein Crystallography |
0.56 |
42 |
16 |
Undulator |
15 |
High Energy |
1.80 |
220 |
20 |
Asymmetric wiggler |
15 |
|
4.0 |
200 |
Superconducting wiggler |
|
16 |
Inelastic Scattering |
0.56 |
42 |
16 |
Undulator |
16 |
|
0.56 |
42 |
16 |
Undulator |
16 |
|
0.36 |
52 |
16 |
Helical undulator |
17 |
Medical |
1.50 |
150 |
24 |
Wiggler |
18 |
Mössbauer |
0.21 |
23 |
16 |
Undulator |
18 |
|
0.42 |
34 |
16 |
Undulator |
19 |
Topography |
1.50 |
150 |
24 |
Wiggler |
20 |
Magnetic Scattering |
1.0 |
210 |
20 |
Asymmetric wiggler |
20 |
|
0.50 |
48 |
20 |
Undulator |
24 |
Dispersive EXAFS |
0.37 |
40 |
20 |
Undulator |
27 |
Heatload Tests |
0.62 |
46 |
16 |
Undulator |
27 |
|
0.65 |
48 |
16 |
Undulator |
27 |
|
0.59 |
44 |
16 |
Undulator |
30 |
High Pressure |
0.52 |
40 |
16 |
Undulator |
30 |
|
0.52 |
40 |
16 |
Undulator |
30 |
|
0.72 |
70 |
16 |
Wiggler |
32 |
Surface Science |
0.50 |
48 |
20 |
Undulator |
32 |
|
0.40 |
40 |
20 |
Undulator |
Table 3: List of all the insertion devices in operation with their period, peak field and minimum magnetic gap.
They are all made of permanent magnets with the exception of a superconducting wiggler installed on ID15.