ESRF Highlights 1996/1997

Table 1: Evolution of the machine’s performance at the ESRF.

Back

PARAMETERS UNITS DESIGN-GOAL ROUTINELY SERVED
(APRIL 1997)
OBJECTIVES
(FOR 1998)
 
Current mA 100 200 200
Associated lifetime hours 8 50 60
Lifetime @ 100 mA hours 8 80 100
Horizontal emittance
H
10-9 mrad 6.2 4 3
Vertical emittance
V
10-12 mrad 620 40 10
ID minimum gap mm 20 16 11
Brilliance at 1 Å
1.6 m undulator
ph/s/mm2/mrad2/0.1%Bwidth 6 x 1017 2.4 x 1019 (low z) 8.8 x 1019 (low z)
Brilliance at 1 Å
5 m undulator
ph/s/mm2/mrad2/0.1%Bwidth 2 x 1018 1.0 x 1020 (low z) 3.8 x 1020 (low z)