ID

APPLICATION

FIELD (t)

PERIOD

GAP (mm)

TYPE

1

Anomalous Scattering

0.85

70

16

Wiggler

1

 

0.56

42

16

Undulator

2

High Brilliance

0.48

46

20

Undulator

2

 

0.16

26

20

Undulator

3

Surface Diffraction

0.48

46

20

Undulator

6

Machine Diagnostics

0.50

48

20

Undulator

9

White Beam

0.85

70

16

Wiggler

9

 

0.62

46

16

Undulator

10

Open/Troika

0.48

46

20

Undulator

10

 

0.71

26

7

Minigap undulator

11

Materials Science

1.20

125

20

Wiggler

12

Circular Polarisation

0.51

85

16

Helical undulator

12

 

0.36

52

16

Helical undulator

13

Microfocus

0.65

46

16

Undulator

14

Protein Crystallography

0.56

42

16

Undulator

15

High Energy

1.80

220

20

Asymmetric wiggler

15

 

4.0

200

Superconducting wiggler

 

16

Inelastic Scattering

0.56

42

16

Undulator

16

 

0.56

42

16

Undulator

16

 

0.36

52

16

Helical undulator

17

Medical

1.50

150

24

Wiggler

18

Mössbauer

0.21

23

16

Undulator

18

 

0.42

34

16

Undulator

19

Topography

1.50

150

24

Wiggler

20

Magnetic Scattering

1.0

210

20

Asymmetric wiggler

20

 

0.50

48

20

Undulator

24

Dispersive EXAFS

0.37

40

20

Undulator

27

Heatload Tests

0.62

46

16

Undulator

27

 

0.65

48

16

Undulator

27

 

0.59

44

16

Undulator

30

High Pressure

0.52

40

16

Undulator

30

 

0.52

40

16

Undulator

30

 

0.72

70

16

Wiggler

32

Surface Science

0.50

48

20

Undulator

32

 

0.40

40

20

Undulator

 

Table 3: List of all the insertion devices in operation with their period, peak field and minimum magnetic gap.