Modelling rocks for oil and gas industry

05-01-2017

Digital rock analysis allows oil and natural gas industry to understand and improve recovery in reservoirs. iRock Technology has managed to get unique images of rock structures by using computed tomography on the ESRF's beamlines.

Share

Company

iRock Technology Co., Ltd. is a rock-core analysis company with headquarters in Beijing, China. iRock offers integrated services and software to the oil and natural gas industry to provide a better understanding of their reservoirs and to improve recovery in conventional and unconventional reservoirs. A key technology to provide these services is called digital rock analysis.

The challenge

Digital rock analysis is a pore-scale imaging and numerical modelling technology to extract nanometre to centimetre scale geological and petrophysical information, as well as multi-phase fluid-flow data based on pore-scale displacement processes from digitized rock samples. One of the benefits of this technology is the capability to provide a large number of rock properties within a very short time compared to traditional physical laboratory experiments.

A prerequisite for calculating representative rock properties are high-quality 3D multi-scale images of a rock sample that capture the representative elementary volume (centimetre-millimetre) and at the same time resolve the finest structures, such as the smallest pores (micrometre-nanometre scale). Computed tomography is currently the best-suited technique to acquire 3D images of rock samples over several decades of length scales.

Due to the fulminant development of benchtop CT and micro-CT hardware during the past decade, it is nowadays possible to image decimetre to millimetre-sized rock samples at voxel sizes of few hundred microns down to one micron at good quality and within an acceptable time of minutes to several hours per sample. However, CT imaging with benchtop micro-CT machines below 1-micron voxel size are of lower quality and are extremely time consuming (>1 day/sample); imaging below 0.5 microns/voxel is not possible at all, in a reasonable time and with acceptable quality.

The crux is that approximately more than 60% of the reservoirs worldwide consist of rocks with very small pore systems, which require imaging at voxel sizes (far) below 1 micrometre with ideal scanning resolutions between 100 and 300 nanometres/voxel.

A partial solution is to use a dedicated nano-CT device for imaging but these machines are delicate with respect to stability, maintenance, flexibility in sample and voxel size and scanning times. So is the maximum sample diameter around 60-70micrometres and the voxel size is fixed to 65 nanometres.

Even if this machine is used in conjunction with micro-CT we are left with a gap in scanning resolution between 65 nanometres and approx. 1 micrometre per voxel. This is unfortunately exactly the voxel-size range required for the majority of reservoirs rocks.

irock1.png
3D digital rock model and geological, petrophysical and fluid-flow data that are commonly extracted.

 

Solution

With their flexibility in energy ranges, spot sizes and detection architecture, beamlines at ESRF can CT-scan our rock samples with varying sample diameters at resolutions ranging from micro- to nano-scale. Due to this capability it is possible to close the resolution gap, which is essential to investigate many reservoir rocks.

A regular micro-CT, imaged at 1 micrometre voxel size, shows that a large proportion of the pore space in the rock is unresolved. On ID19, by imaging at 280 nanometres per voxel the results do not show partial volume effects and resolve the entire pore space (Fig. 2).

The effects of unresolved voxels in digital rock analysis are dramatic, since a clear segmentation of the rock phases is not possible. Every voxel layer that is classified into a wrong rock phase can offset subsequent calculations by orders of magnitude and leads to inadequate simulation results.

Access to the ESRF beamlines offers quick and high-quality imaging at flexible voxel sizes and a range of sample sizes, which is not achievable with laboratory CT machines. The acquired images provide a profound base to build representative 3D digital rock models and extract rock properties at a high confidence level.

Benefits

Next to the image quality, the higher sample throughput compared to laboratory devices helps iRock to plan and conduct projects for the oil and gas industry in shorter time. The oil and gas companies, in turn, benefit from great time savings in comparison to their traditional methods - weeks and months instead of several years for a typical project.

irock2.png

Comparison of a carbonate rock imaged with conventional micro-CT (upper panel; 2mm side length, 1 micro-metre voxel size) and synchrotron CT (lower panel; 0.5 mm side length, 280 nm voxel size). To the left are the 3D volumes, to the right are 2D slices across. Black colour is pore space, light grey indicates solid grains and intermediate grey shades are unresolved voxels (partial volume effect).