Vanadium data in eV
EK ΔEK EL1 ΔEL1 EL2 ΔEL2 EL3 ΔEL3 EKα1 ΔEKα1 EKα2 ΔEKα2 EKß1
5465 1.01 626.7 2.41 519.8 0.26 512.1 0.24 4952.2 1.26a / 1.75b 4944.64 1.28a / 2.38b 5427.29

 

Main beamline parameters at K-edge
Bending Magnet Monochromator Mirrors
Vertical div. (mrad) Cristal type Angle (°) Resolution (eV) Angle (mrad) Cut-off energy (keV)
0.240 Si(220) 36.26 0.280 7.1 8.2
Si(111) 21.24 0.747

 

Main crystal analyzer spectrometer parameters at K-edge
Line Crystal
Name E (eV) Type Bragg angle (°)
EKα1 4952.2 Ge(331) 74.70
EKß1 5427.29 Ge(422) 81.562
Si(331) 66.463

Calibration spectra

Publications with data measured at FAME at this edge can be found in the beamline bibliography webpage.

Spectra measured at this edge can be searched via our SSHADE database webpage.